Brand Name : Macy
Model Number : AA-1800H
Certification : CE/ISO/ROHS/FCC/FDA
Place of Origin : China
MOQ : 5pcs
Price : Negotiable
Payment Terms : T/T,Western Union
Supply Ability : 1000pcs/month
Delivery Time : Received payment,within 10 days of delivery
Packaging Details : Carton packaging, plus a wooden
Product Name : Photometer
Source Type : Hollow cathode lamps
Wavelength range : 180~900nm
Spectral Bandwidth : 0.1/0.2/0.4/1.0/2.0nm
Wavelength accuracy : ≤0.15nm
Absorbance Range : 0-4A
Heating temperature Atomic Absorption photometer 180 - 900nm Wavelength
Specifications:
| Mainframe | |
| Model: | AA-1800H |
| Light Source: | ≤6 lamps automatic turret, automatic alignment |
| Power Supply: | 110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
| Lamp Current: | pulsed power supply |
| Optical System: | large 1800 /mm grating ruling, full closed optical system |
| Wavelength Range: | 180nm-900nm |
| Automatically peak find,a key opticaloptimization function | |
| Wavelength Accuracy: | ≤0.15nm |
| Wavelength Repeatability: | ±0.1nm |
| Spectral Bandwidth: | 0.1nm,0.2nm,0.4nm,1.0nm,2.0nm |
| (5 steps with automatic changeover) | |
| Baseline Stability: | ≤±0.002A/30 min (Static) |
| ≤±0.005A/30min (Dynamic) | |
| Absorbance Range: | 0-4A |
| Detector: | imported photomultiplier tube |
| Flame Analytical System | |
| Burner Head: | full titanium combustion head, 50mm or 100mm generalcombustion head |
| Atomization Chamber: | polymer explosion-proof spray chamber |
| Nebulizer: | atomizer efficient glass atomizer, can also be customized |
| Ignition Type: | microcomputer control, automatic ignition |
| Gas Control: | automatic gas control system |
| Detection Limits(Cu): | 0.002μg/mL |
| Precision: | RSD≤0.5% |
| Graphite Furnace Analytical System | |
| Heating Mode: | vertical heating |
| Temperature Control Method: | vertical optical temperature monitoring graphite tube wall temperature |
| Temperature Range: | room temperature to 3000℃ |
| The Program: | automatic temperature control up to 20 order |
| Temperature Control: | the furnace enriched up to 20 times |
| Characteristics Volume: | 0.5 × 10-12g (Cd) |
| Detection Limit: | 0.4 × 10-12g (Cd) |
| Precision: | RSD≤3% |
| The Cooling Water: | can choose cooling water circulation system |
| Safety: | the graphite tube damage, water flow |
| air pressure and other alarmtemperature overheating protection | |
| Autosampler Graphite Furnace | |
| Sample Tray: | 70 sample cups, 6 reagent cup |
| Sample Volume: | 1-100μl |
| The Smallest Lincrement: | 0.1 μl |
| The Volume of Sample | better than 1%(at the time of 10mL-100mL) |
| Repeatability Volume | |
| Repeated Sampling Frequency: | up to 99 Times |
| Cleaning and Waste | each 500mL |
| Container Volume | |